REXROTH-VT-11023-14-Electric amplifier modules Simple Type: Amplifier

The amplifier module is clipped onto carrier rails such as those commonly installed in electronic control cabinets. The electric connection is via a terminal strip. The amplifier module contains the electronic components for the control of two proportional solenoids. Depending on the command value polarity solenoid "a" or "b" is controlled. The actual value (position of valve spool) is signaled by an inductive transducer measuring system and compared to the externally signaled command value. Occurring differences between actual and command value are leveled out.Through the connection of a positive voltage (U F > 8,5 V) at terminal 3 the controller and the output stage are released. The following may be set via an external trimming potentiometer: the ramp time up to ca. 5 s a command value reduction in the range from 0 % to 100 % the zero point of the position transducer

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • "H1"multifunction indicator (orange)
  • Adjustable ramp generator (max ramp time 5 s)
  • Cable break recognition
  • Controller for the valve spool position
  • Controller release
  • LED-displays: "power"internal supply voltage (green)
  • Oscillator and demodulator for the inductive positioning signalling
  • Polarity safeguard for the voltage supply
  • Step function generator (only with VT 11 023 and VT 11 024)
  • Two pulsed current output stages

Specifications

    General
  • Actual position value x: 0 to ± 5 V
  • Command value w: 0 to ± 5 V
  • Demodulator Input (positional measuring system): > 50 k?
  • Differential input (command value input): 0 to ± 10 V; Re 50 k? (standard 1)
  • Disturbance resistance Class: 3 to prEN 50082 T2 2)
  • Function range: upper limit value + 35 V
  • FUSE: 3 A; sluggish; after release self-activating
  • Housing dimensions (W x H x D): 40 x 79 x 85,5 mm
  • Inactive: < 6,5 V
  • lower limit value: + 21 V
  • Max. capacity: 30 mA
  • Max. current consumption: 2 A
  • Max. stroke of transducer: VT 11023 s 2,8 mm
  • Mechanical load ability: to DIN/IEC 68-2, T6, T24 and T27 2)
  • Operating voltage: + 24 VDC + 40 % –10 %
  • Oscillator frequency: 5,8 kHz ± 10 %
  • Output stage: Solenoid current/resistance VT 11023 Imax 1,8 A; R(20) 5,4 ?
  • Permissible temperature range: 0 to 50 °C to DIN/IEC 68-2, T1, T2, T14 and T30 2)
  • Pulse frequency: freely pulsating up to ca. 1,5 kHz
  • Ramp time (setting range): 10 ms to 5 s
  • Release active: 8,5 V < U F < 40 V
  • Storage temperature range: t – 25 to + 85 °C to DIN/IEC 68-2, T1 and T2 2)
  • Type of connection: 12-pin terminal strip
  • Voltage amplitude: (USS)5 V per output
  • Weight: m 0,14 kg

 

Applications

  • None Available

Aliases